Abstract
Wireless MEMS sensors have common features such as wireless communication, data measurement, embedded processing, battery-based self-power, and low cost, and increased measurement effectiveness. Wireless MEMS sensors enable efficient SHM without interfering with location because there is no requirement for triboelectric noise and cumbersome cables. However, there is little research on the communication distance with sensors and data. For instance, existing researches have limited communication distance experiments in civil engineering bridges. It is also necessary to investigate the characteristics of dynamic behavior and the communication distance of architectural structures with different wireless transmission/reception environments. Therefore, in a building structure with walls and slabs instead of open spaces, MEMS sensors and data loggers were used as distance experiments where communication disturbance between the vertical slab and the horizontal wall could actually be communicated.
| Translated title of the contribution | The Evaluation of Communication Distance Using Wireless MEMS Sensor in Building Structure |
|---|---|
| Original language | Korean |
| Pages (from-to) | 93-102 |
| Number of pages | 10 |
| Journal | 한국공간구조학회지 |
| Volume | 17 |
| Issue number | 4 |
| DOIs | |
| State | Published - Dec 2017 |