Abstract
Lithium-ion batteries have been used for high density energy storage system due to the features such as low self-discharge rate. And the unit cell battery with the voltage less than 4V is recommended to use the series connections for a high voltage charger. When batteries are charged or discharged with series connection, there may be an explosion or degradation of unit cell battery owing to undistributed internal resistance of cell battery. therefore, the voltages of unit cell batteries should be monitored to prevent an overcharging and a deep discharging. This paper introduces the implementation of CVM (Cell Voltage Monitoring) system that can transmit the 12 channel's information including voltages and temperatures with the 12-bits resolutions and the transmission speed of 192 kbps.
Translated title of the contribution | Implementation of Cell Voltage Monitoring System for Monitoring Multi-channel Battery |
---|---|
Original language | Korean |
Pages (from-to) | 15-19 |
Number of pages | 5 |
Journal | 통신위성우주산업연구회논문지 |
Volume | 8 |
Issue number | 3 |
State | Published - Sep 2013 |