리튬 이온 배터리의 냉각 채널에서 유동 방향이 열전달 특성에 미치는 영향

Translated title of the contribution: Effect of Flow Direction on Heat Transfer Characteristics in the Cooling Channel in Lithium-Ion Battery

Research output: Contribution to journalArticlepeer-review

Abstract

The effect of flow direction on heat transfer in water cooling channel of lithium-ion battery is numerically investigated. Battery Design StudioⓇ software is used for modeling electro-chemical heat generation in the battery and the conjugated heat transfer is analyzed with the commercial package STAR-CCM+. The result shows that the maximum temperature and temperature difference of battery with Type 1 are the lowest because the heat transfer in the entrance region near the electrode is enhanced. As the inlet velocity is increased, the maximum temperature and temperature difference of battery decreases but the pressure loss increases. The pressure loss in Type 2 channel is the lowest due to the shortest channel length, while the pressure loss with Type 3 or 4 channel is the highest because of the longest channel length. Considering heat transfer performance and pressure loss, Type 1 is the best cooling channel.
Translated title of the contributionEffect of Flow Direction on Heat Transfer Characteristics in the Cooling Channel in Lithium-Ion Battery
Original languageKorean
Pages (from-to)1089-1095
Number of pages7
Journal한국기계기술학회지
Volume22
Issue number6
DOIs
StatePublished - Dec 2020

Fingerprint

Dive into the research topics of 'Effect of Flow Direction on Heat Transfer Characteristics in the Cooling Channel in Lithium-Ion Battery'. Together they form a unique fingerprint.