멤스 기반의 캔틸레버 형 전극을 가진 마이크로 디바이스를 이용한 단일세포의 Electroporation 및 유전자 Transfection

Translated title of the contribution: Single-cell Electroporation and Gene Transfection using MEMS-based Microdevice with Cantilever-type Microelectrode

Research output: Contribution to journalArticlepeer-review

Abstract

In this paper, we present details on fabrication of single-cell electroporation microdevice, practical experiments of single-cell electroporation with our fabricated microdevice. Also, the continuous electroporation for the continuous flow of cells is used for high-throughput electroporation. The delivery efficiency and cell viability tests are provided and the successful GFP transfection into cells is also evaluated with a fluorescent microscope after electroporation. This device enables to reduce the size of samples and thus the use of small amount of reagents. Also, it makes it possible to permit to avoid cell discrimination (transfected cells versus non-transfected cells)encountered when traditional bulk electroporation is held.
Translated title of the contributionSingle-cell Electroporation and Gene Transfection using MEMS-based Microdevice with Cantilever-type Microelectrode
Original languageKorean
Pages (from-to)85-91
Number of pages7
Journal한국정밀공학회지
Volume27
Issue number5
StatePublished - May 2010