Abstract
This study has been purposed to provide thermal comfort range in accordance with the residential style of radiant floor heating space, and to compare it with the thermal comfort range at predicted mean vote. The survey for the thermal sensation vote to the subjects and the measurement of environmental factors has been executed, and regression analysis has been performed. It is interpreted that the combination of the physical factor and the psychological factor results lower neutral point of the floor sitting style than that of the chair sitting style. There are some difference between the measured predicted mean vote and the thermal sensation vote via survey, which appears to be caused by distinctive heat transfer characteristic of floor radiant heating space, such as, high radiant temperature and contact thermal sensation of floor surface.
| Translated title of the contribution | Thermal Comfort Range of Radiant Floor Heating System by Residential Style |
|---|---|
| Original language | Korean |
| Pages (from-to) | 7-14 |
| Number of pages | 8 |
| Journal | 한국지열에너지학회논문집 |
| Volume | 11 |
| Issue number | 1 |
| DOIs | |
| State | Published - Mar 2015 |