Abstract
The fuel cell is one of the renewable energy sources. And it is a new source of energy that can be applied to various fuels and continuously supported by the excellent city-gas infrastructure. It is important to improve performances and reliabilities, and reduce the cost of fuel cell systems for commercialization. And, some safety performances of blower domestically produced are evaluated and some improvements are researched to save the cost of fuel cell systems. In this paper, the performance and worst stress condition of blowers are evaluated in operating environment similar to the fuel cell systems. Actually, the correlation of flow, leakage and thermal behavior are evaluated in the worst stress condition at $70^{\circ}C$ and, some major factors of blower degradation such as a motor deterioration, material and structures of the outlet are examined.
| Translated title of the contribution | A Study on the Worst Stress Condition Test Evaluation of Blowers for Small Stationary Fuel Cell System |
|---|---|
| Original language | Korean |
| Pages (from-to) | 34-40 |
| Number of pages | 7 |
| Journal | 한국가스학회지 |
| Volume | 16 |
| Issue number | 6 |
| DOIs | |
| State | Published - Dec 2012 |