Abstract
As the occurrence rate of terror and hazard is increasing throughout the world, GSA, DoD, and FEMA are proceeding a study about mitigating the damage of terror. Korea is no more a safe place from the terrorist's threat, so we need to make measures against them. In this study we developed modified RVS System by revising some items to adjust the system to the domestic condition and conducted a risk assessment on several tall buildings in Korea. By using IRVS system which is developed by DHS, we also carried out the risk assessment. Comparing the results between RVS with IRVS, we performed terror risk evaluation of tall buildings. Through risk assessment of several tall buildings, we analyzed key factors of each scenarios and suggested the mean value of each items, so we would like to help the counter-terrorism in the design phase.
| Translated title of the contribution | Risk Assessment of Tall Buildings in Korea by comparative study of Modified RVS and IRVS system |
|---|---|
| Original language | Korean |
| Pages (from-to) | 91-98 |
| Number of pages | 8 |
| Journal | 한국공간구조학회지 |
| Volume | 12 |
| Issue number | 4 |
| DOIs | |
| State | Published - Dec 2012 |