아라미드 스트립을 이용한 학교건축물의 내진성능 보강방안에 관한 실험적 연구

Translated title of the contribution: Experimental Study on Seismic Retrofitting Methods for School Building using Aramid Strip

Research output: Contribution to journalArticlepeer-review

Abstract

Most of the school buildings were built before the seismic code was established. To consider the sunlight and ventilation to the partition walls are built about 1m height beside columns at typical school buildings. For the reason, columns which is consisted school building occur brittle failure shape by the reduced effective depth. In this study, experimental test for retrofitting effect by Aramid Fiber Reinforced Polymers(AFRP) strips on masonry infilled reinforced concrete(RC) frames is performed. The test results were to ensured enough time to evacuate due to the enhancement of ductility and strength of school buildings to withstand earthquakes using AFRP strips.
Translated title of the contributionExperimental Study on Seismic Retrofitting Methods for School Building using Aramid Strip
Original languageKorean
Pages (from-to)100-106
Number of pages7
Journal한국안전학회지
Volume25
Issue number3
StatePublished - Jun 2010