적외선 열화상 이미지 컨트라스트 파라미터를 이용한 결함 크기의 비파괴 평가

Translated title of the contribution: Nondestructive Evaluation of Defect Size by Using a Contrast Parameter of Infrared Image

Research output: Contribution to journalArticlepeer-review

Abstract

Purpose: In this study, the defect quantification of thin metal plate was evaluated by using lock-in infrared thermography.
Methods: A STS304 standard specimens, which had the artificial-defects of different size, were used. The focal distance between the infrared camera and the specimen was set to 500mm, and the distance between the lump and the specimen was set to 200mm. One halogen lamp with a maximum capacity of 1kW was used, and phase-lock infrared thermal images with a frequency of 1Hz were captured and analyzed.
Result: Objectively quantified data values were obtained by analyzing the contrast ratio and signal-to-noise ratio.
Conclusion: The possibility of defect diagnosis for thin metal plate was confirmed by using the lock-in infrared thermography technique.
Translated title of the contributionNondestructive Evaluation of Defect Size by Using a Contrast Parameter of Infrared Image
Original languageKorean
Pages (from-to)87-94
Number of pages8
Journal신뢰성 응용연구
Volume18
Issue number1
DOIs
StatePublished - Mar 2018

Fingerprint

Dive into the research topics of 'Nondestructive Evaluation of Defect Size by Using a Contrast Parameter of Infrared Image'. Together they form a unique fingerprint.

Cite this