정전기 방전에너지에 따른 LPG/공기 혼합물의 폭발특성에 관한 실험적 연구

Translated title of the contribution: Experimental Investigations on Explosion Characteristics of LPG/Air Mixture by Electrostatic Discharge Energies

Research output: Contribution to journalArticlepeer-review

Abstract

Experimental investigations were performed to examine the effects of different electrostatic discharge ignition energies on LPG/air mixture explosions in an explosion chamber. The chamber consisted of 500 mm in length, with a 100×100 mm2 cross section. Three different ignition energies were used: 0.30 mJ, 46 mJ and 98 mJ. Flame propagations were recorded by a high speed video camera. The results of flame speed and pressure obtained from the different ignition energies were discussed. It was found that as the energy increased, different flame initiations occurred. This caused the time interval in both the flame and pressure developments. It was also found that the flame speed and the pressure were less sensitive to both 0.30 mJ and 46 mJ, except for the ignition energy of 98 mJ
Translated title of the contributionExperimental Investigations on Explosion Characteristics of LPG/Air Mixture by Electrostatic Discharge Energies
Original languageKorean
Pages (from-to)26-30
Number of pages5
Journal한국안전학회지
Volume26
Issue number6
DOIs
StatePublished - Dec 2011

Fingerprint

Dive into the research topics of 'Experimental Investigations on Explosion Characteristics of LPG/Air Mixture by Electrostatic Discharge Energies'. Together they form a unique fingerprint.

Cite this