Abstract
Steel braced frames are commonly used because braced frames are one of the most economical and efficient seismic resisting systems. However, research into the behavior of multi-story X-braced frame systems with mid-span gusset plates, as used in practice, is limited. As a result, their seismic performance and the influence of connection design on this performance are not well understood. Detailed nonlinear computer analyses of the frame were performed prior to building the test specimens and were used to aid the design and to predict the system performance. These analyses suggested significantly different behavior for the midspan gusset plate than that noted for the corner gusset plate connections. This paper summarizes the results of a full scale, 2-story braced frame analysis and test on concentrically braced frames.
| Translated title of the contribution | Effect of Mid-span Gusset Plates on the Behavior of Multi-Story X-Braced Frames |
|---|---|
| Original language | Korean |
| Pages (from-to) | 179-186 |
| Number of pages | 8 |
| Journal | 한국강구조학회 논문집 |
| Volume | 25 |
| Issue number | 2 |
| DOIs | |
| State | Published - Apr 2013 |