Abstract
For train vibration influence assessment of newly constructed buildings in building design levels, 4 train measured vibration acceleration responses were used to compare with TR theory values and suitability of TR values was proposed. Through this TR method, construction planned grounds located near railroad areas were selected and ground vibration measurement was conducted. Through natural frequency by MIDAS, vertical acceleration response, and ground frequency from measured vibration response, TR was calculated and vibration prediction was conducted. As a result of comparing acceleration response estimate applying TR and measured value of train vibration acceleration response, it was found that it was in 3.61% ∼ 37.1% of margin of error. Clear peak of 7.19~10.61Hz in KTX, Gyungeuisun, and cement train were confirmed.
| Translated title of the contribution | Transmissibility Effect Evaluation of Buildings Near Railroad Areas |
|---|---|
| Original language | Korean |
| Pages (from-to) | 132-139 |
| Number of pages | 8 |
| Journal | 한국공간구조학회지 |
| Volume | 11 |
| Issue number | 1 |
| DOIs | |
| State | Published - Mar 2011 |