코일철근의 표면 거칠기 물리량 평가 기술

Translated title of the contribution: An Evaluation Technique of Surface Roughness of Corroded Reinforcing Bar-in-Coils

Research output: Contribution to journalArticlepeer-review

Abstract

This paper discusses the surface roughness of corroded reinforcement rebar-in-coil focusing on the quantitative measurement technique using 3D scanner. Reinforcement rebar-in-coil was stacked in site for 0 day, 3 days, 7 days, 14 days and 21 days. And rebar-in-coil was corroded 0.04%, 0.3367%, 0.6157%, 0.7898%, and 1.1965% respectively. Using 3-dimensional scanner, each surface profile of reinforcement rebar-in-coil was established, and surface roughness was measured. Through the tests and analyses of corroded rebar-in-coil, the increase of fractal dimension for each rebar-in-coil was measured as 0.0216, 0.0235, 0.028, 0.0319, and 0.0455 for different stacked periods. Therefore, surface assessment technique using fractal dimension showed similar results with the actual corrosion rate.
Translated title of the contributionAn Evaluation Technique of Surface Roughness of Corroded Reinforcing Bar-in-Coils
Original languageKorean
Pages (from-to)6551-6557
Number of pages7
Journal한국산학기술학회 논문집
Volume16
Issue number10
DOIs
StatePublished - Oct 2015

Fingerprint

Dive into the research topics of 'An Evaluation Technique of Surface Roughness of Corroded Reinforcing Bar-in-Coils'. Together they form a unique fingerprint.

Cite this