플랜트 부품용 상용 발수코팅의고온 환경 고장 특성 비교 분석

Translated title of the contribution: Failure Analysis of Commercial Water-Repellent Coatings for High Temperature Plant

Research output: Contribution to journalArticlepeer-review

Abstract

Purpose: The purpose of this study is to evaluate failure characteristic and mechanism of four commercial water-repellent coatings for elevated temperature machinery applications.
Method: Thermal degradation was performed for up to 64 thermal cycles. 1 cycle consists of 15 minute holding at 523K under 300rpm revolution and 15 minute-natural cooling. Contact angle was measured and microstructure of the coating layer was observed by using a scanning electron microscope.
Results: Four kinds of commercial repellent coating showed hydrophobic or super-hydrophobic property implying that all coatings are suitable for room temperature application. Contact angle of three kinds of commercial coatings decreased rapidly after thermal exposure, while only one specimen having hydrophobic surface showed extremely slow degradation.
Conclusion: Observed decrease in contact angle of the coatings were attributed to formation of macro-sized pores and disappearance of micro-protrusion during thermal exposure. Optimum water-repellent coating needs to be selected under the consideration of initial contact angle as sell as service temperature.
Translated title of the contributionFailure Analysis of Commercial Water-Repellent Coatings for High Temperature Plant
Original languageKorean
Pages (from-to)78-82
Number of pages5
Journal신뢰성 응용연구
Volume17
Issue number1
StatePublished - Mar 2017

Fingerprint

Dive into the research topics of 'Failure Analysis of Commercial Water-Repellent Coatings for High Temperature Plant'. Together they form a unique fingerprint.

Cite this