휨과 전단을 고려한 철근콘크리트 방호벽 성능에 관한 연구

Translated title of the contribution: Bending and Shear Capacity of Reinforced Concrete Protective Wall

Research output: Contribution to journalArticlepeer-review

Abstract

With the recent increase in gas energy use, risk management for explosion accidents has been emphasized. Protective walls can be used to reduce damage from explosions. The KOSHA GUIDE D-65-2018 suggests the minimum thickness and height of protective walls, minimum reinforcement diameter, and maximum spacing of reinforcements for the structural safety of the protective walls. However, no related evidence has been presented. In this study, the blast load carrying capacity of the protective wall was analyzed by the pressure-impulse diagrams while changing the yield strength of the reinforcement, concrete compressive strength, reinforcement ratio, protective wall height, and thickness, to check the adequacy of the KOSHA GUIDE. Results show that failure may occur even with design based on the criteria presented by KOSHA GUIDE. In order to achieve structural safety of protective walls, additional criteria for minimum reinforcement yield strength and maximum height of protective wall are suggested for inclusion in KOSHA GUIDE. Moreover, the existing value for minimum reinforcement ratio and the thickness of the protective wall should be increased.
Translated title of the contributionBending and Shear Capacity of Reinforced Concrete Protective Wall
Original languageKorean
Pages (from-to)44-51
Number of pages8
Journal한국안전학회지
Volume38
Issue number2
DOIs
StatePublished - 2023

Fingerprint

Dive into the research topics of 'Bending and Shear Capacity of Reinforced Concrete Protective Wall'. Together they form a unique fingerprint.

Cite this