Abstract
This study provides a robust control of a grid-connected three-phase two-level photo voltaic inverter. The introduced control method uses the cascade control strategy to regulate AC-side current and DC-link voltage. A robust controller with integration action is used for the inner-loop AC-side current control, which maximizes the convergence rate using a linear matrix inequality-based optimization design method and eliminates the offset error. The robust controller design method considers the parameter uncertainty set to accommodate parameter mismatch and un-modeled components in the inverter model. An outer-loop proportional?integral controller is used to regulate DC-link voltage with linearization of DC/AC relation. The proposed control strategy is applied to a grid-connected 100 kW photo voltaic inverter.
| Translated title of the contribution | Robust Control of a Grid Connected Three-Phase Two-Level Photovoltaic Inverter |
|---|---|
| Original language | Korean |
| Pages (from-to) | 538-548 |
| Number of pages | 11 |
| Journal | 전력전자학회 논문지 |
| Volume | 19 |
| Issue number | 6 |
| DOIs | |
| State | Published - Dec 2014 |