A Method for Real Time Monitoring of Oxide Thickness in Plasma Electrolytic Oxidation of Titanium

Research output: Contribution to journalArticlepeer-review

Abstract

During PEO (plasma-electrolytic-oxidation) treatment of titanium, the relationship between the thickness of oxide film and the measured electrical information was investigated. A simple real time monitoring method based on the electrical information being gathered during PEO treatment is proposed. The proposed method utilizes the current flowing from a high frequency voltage source to calculate the resistance of an oxide film, which is converted into the thickness of an oxide film. This monitoring method can be implemented in PEO system in which an oxide film is grown by constant or pulsed voltage/current sources.
Original languageEnglish
Pages (from-to)8-11
Number of pages4
JournalCORROSION SCIENCE AND TECHNOLOGY
Volume9
Issue number1
StatePublished - Feb 2010

Fingerprint

Dive into the research topics of 'A Method for Real Time Monitoring of Oxide Thickness in Plasma Electrolytic Oxidation of Titanium'. Together they form a unique fingerprint.

Cite this