Abstract
An improved stationary-frame-based current control scheme for a permanent-magnet synchronous motor (PMSM) is presented. To improve the current control performance in the stationary frame, the disturbance is estimated using the time-delay control. The proposed scheme is implemented on a PMSM using digital signal processor TMS320C31 and the effectiveness is verified through the comparative experiments.
Original language | English |
---|---|
Pages (from-to) | 1065-1068 |
Number of pages | 4 |
Journal | IEEE Transactions on Industrial Electronics |
Volume | 50 |
Issue number | 5 |
DOIs | |
State | Published - Oct 2003 |
Keywords
- Current control
- Disturbance estimation
- Permanent-magnet synchronous motor (PMSM)
- Stationary reference frame