Abstract
An improved stationary-frame-based current control scheme for a permanent-magnet synchronous motor (PMSM) is presented. To improve the current control performance in the stationary frame, the disturbance is estimated using the time-delay control. The proposed scheme is implemented on a PMSM using digital signal processor TMS320C31 and the effectiveness is verified through the comparative experiments.
| Original language | English |
|---|---|
| Pages (from-to) | 1065-1068 |
| Number of pages | 4 |
| Journal | IEEE Transactions on Industrial Electronics |
| Volume | 50 |
| Issue number | 5 |
| DOIs | |
| State | Published - Oct 2003 |
Keywords
- Current control
- Disturbance estimation
- Permanent-magnet synchronous motor (PMSM)
- Stationary reference frame
- Time-delay control