T1 - Applicability of LC-MS/MS for the Determination of Acrylamide in Stack Gas
T2 - Comparison with HPLC-DAD
AU - Im, Minji
AU - Kang, Daeil
AU - Kim, Rhokho
AU - Kim, Daekeun
N1 - Publisher Copyright:
© 2026, Korean Society for Atmospheric Environment. All rights reserved.
PY - 2026
Y1 - 2026
N2 - This study evaluated the applicability of high-performance liquid chromatography coupled with diode array detection (HPLC-DAD) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) for determining acrylamide in industrial stack gas. When the OSHA PV 2004 method based on HPLC-DAD was applied to stack gas samples, matrix interference was observed near the acrylamide retention time. Blank sample analysis indicated that the interference originated from residual components in the XAD-7 sorbent, and a conditioning procedure consisting of four successive extractions with 5% methanol/95% water effectively removed the interference. An LC-MS/MS method based on the Korean Standard Method for Water Quality (ES 04609.2) was adapted for application to stack gas samples using acrylamide-13C3 as an internal standard. The LC-MS/MS method showed a method detection limit of 0.047 µg/m3, whereas the HPLC-DAD method showed 0.70 µg/m3. Field application to 25 stack outlets from 9 industrial facilities detected acrylamide at 6 outlets, with concentrations ranging from 0.168 to 2,801 µg/m3 by LC-MS/MS. This broad concentration range indicates substantial variability in acrylamide emissions among industrial sources and the need for an analytical method applicable over a wide concentration range. Two samples were quantified by both methods, whereas four samples were quantified only by LC-MS/MS. These results indicate that HPLC-DAD with sorbent conditioning is applicable to high-concentration emission sources, while LC-MS/MS is more suitable for low-concentration sources or samples affected by matrix interference.
AB - This study evaluated the applicability of high-performance liquid chromatography coupled with diode array detection (HPLC-DAD) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) for determining acrylamide in industrial stack gas. When the OSHA PV 2004 method based on HPLC-DAD was applied to stack gas samples, matrix interference was observed near the acrylamide retention time. Blank sample analysis indicated that the interference originated from residual components in the XAD-7 sorbent, and a conditioning procedure consisting of four successive extractions with 5% methanol/95% water effectively removed the interference. An LC-MS/MS method based on the Korean Standard Method for Water Quality (ES 04609.2) was adapted for application to stack gas samples using acrylamide-13C3 as an internal standard. The LC-MS/MS method showed a method detection limit of 0.047 µg/m3, whereas the HPLC-DAD method showed 0.70 µg/m3. Field application to 25 stack outlets from 9 industrial facilities detected acrylamide at 6 outlets, with concentrations ranging from 0.168 to 2,801 µg/m3 by LC-MS/MS. This broad concentration range indicates substantial variability in acrylamide emissions among industrial sources and the need for an analytical method applicable over a wide concentration range. Two samples were quantified by both methods, whereas four samples were quantified only by LC-MS/MS. These results indicate that HPLC-DAD with sorbent conditioning is applicable to high-concentration emission sources, while LC-MS/MS is more suitable for low-concentration sources or samples affected by matrix interference.
KW - Acrylamide
KW - Emission analysis
KW - HPLC-DAD
KW - LC-MS/MS
KW - Matrix interference
KW - Stack gas
UR - https://www.scopus.com/pages/publications/105044016160
U2 - 10.5572/KOSAE.2026.42.2.369
DO - 10.5572/KOSAE.2026.42.2.369
M3 - Article
AN - SCOPUS:105044016160
SN - 1598-7132
VL - 42
SP - 369
EP - 381
JO - Journal of Korean Society for Atmospheric Environment
JF - Journal of Korean Society for Atmospheric Environment
IS - 2
ER -