Skip to main navigation Skip to search Skip to main content

Automated quantitative assessment of myocardial perfusion in rodent PET/SPECT images

  • Sang Keun Woo
  • , Yong Jin Lee
  • , Kyeong Min Kim
  • , Jung Woo Yu
  • , Kyo Chul Lee
  • , Min Hwan Kim
  • , Ji Ae Park
  • , Joo Hyun Kang
  • , Byung Il Kim
  • , Sang Moo Lim
  • Korea Institute of Radiological and Medical Sciences

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

The aim of this study was to automatically assessment of the 64Cu-PTSM, 99mTc-MIBI and 201Tl myocardial perfusion image using Multi Gaussian Mixture Model (MGMM). Myocardial infarction (MI) model was prepared through permanently ligated left circumflex artery of rats. PET/SPECT images were acquired using small animal PET/SPECT scanner (InveonTM, Siemens) with physiological monitoring system (BioVet, m2m Imag. Corp.). PET images were obtained at 10 min post injection of 37 MBq/0.2 mL of 64Cu-PTSM via tail vein as list-mode data. SPECT images were acquired at 60 min post IV injection of 110 MBq of Tc99m-MIBI and Tl-201/0.1 mL with 126-154 keV (Tc), 63-77 keV (Tl) energy window and 1.0 mm pinhole collimator. The acquired data was reconstructed by OSEM2D algorithm with 4 iterations. To automatically make the myocardial contour and generate polar map, we used Cedars-Sinai method. Myocardial infarct region of polar map were evaluated by using MGMM method for adaptive threshold calculation and predefined threshold method for absolute threshold calculation. Rat myocardium was stained by hematoxylin and eosin (H&E) for reference value of infarct size after the imaging. The infarct size of PET/SPECT image was defined by infarction area percentage of the total left myocardium. Comparative analysis was performed between MI size of histology and polar map. The size difference in 64Cu-PTSM PET polar map was 6.96 3.53% from the absolute value 40% and 4.40 0.58% from MGMM4. The difference in 99mTc-MIBI SPECT polar map was 8.87 1.16% from the absolute value 40%, and 3.47 1.99% from MGMM4. The difference in 201Tl SPECT polar map was 11.73 1.45% from the absolute value 40%, and 2.97 1.46% from MGMM4. MGMM method showed the possibility of quantitative evaluation for myocardial perfusion in rat polar maps. Automatic infarct area measurement is expected to contribute significantly to the research of heart disease in nuclear medicine image.

Original languageEnglish
Title of host publication2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record, NSS/MIC 2012
Pages3054-3057
Number of pages4
DOIs
StatePublished - 2012
Event2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record, NSS/MIC 2012 - Anaheim, CA, United States
Duration: 29 Oct 20123 Nov 2012

Publication series

NameIEEE Nuclear Science Symposium Conference Record
ISSN (Print)1095-7863

Conference

Conference2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record, NSS/MIC 2012
Country/TerritoryUnited States
CityAnaheim, CA
Period29/10/123/11/12

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Fingerprint

Dive into the research topics of 'Automated quantitative assessment of myocardial perfusion in rodent PET/SPECT images'. Together they form a unique fingerprint.

Cite this