Chemoresistive Sensor Readout Circuit Design for Detecting Gases with Slow Response Time Characteristics

Dong Yeon Lee, Joon Boo Yu, Hyung Gi Byun, Hyeon June Kim

Research output: Contribution to journalArticlepeer-review

13 Scopus citations

Abstract

Based on an analysis of the signal characteristics of gas sensors, this work presents a chemoresistive sensor readout circuit design for detecting gases with slow response time characteristics. The proposed readout circuit directly generates a reference voltage corresponding to the initial value of the gas sensor and extracts only the amount of gas concentration change in the sensor. Because the proposed readout circuit can adaptively regenerate the suitable reference voltage under various changing ambient conditions, it can alleviate the variation in output values at the same gas concentration caused by non-uniformities among gas sensors. Furthermore, this readout circuit effectively eliminates the initial value shifts due to the poor reproducibility of the gas sensor itself without requiring complex digital signal calibrations. This work focuses on a commercially viable readout circuit structure that can effectively obtain slow response gas information without requiring a large capacitor. The proposed readout circuit operation was verified by simulations using spectre in cadence simulation software. It was then implemented on a printed circuit board with discrete components to confirm the effectiveness with existing gas sensor systems and its commercial viability.

Original languageEnglish
Article number1102
JournalSensors
Volume22
Issue number3
DOIs
StatePublished - 1 Feb 2022

Keywords

  • Chemoresistive sensor
  • Gas sensor
  • Offset tracking readout
  • Readout circuit
  • Slow response gas sensing

Fingerprint

Dive into the research topics of 'Chemoresistive Sensor Readout Circuit Design for Detecting Gases with Slow Response Time Characteristics'. Together they form a unique fingerprint.

Cite this