Coalescence evaluation of collinear axial through-wall cracks in steam generator tubes

Yoon Suk Chang, Nam Su Huh, Young Jin Kim, Jin Ho Lee, Young Hwan Choi

Research output: Contribution to journalArticlepeer-review

6 Scopus citations

Abstract

To maintain the structural integrity of steam generator tubes, usually, 40% of wall thickness plugging criterion has been adopted. However, since the criterion is applicable only for the steam generator tube containing a single crack, the interaction effect of multiple cracks cannot be considered. In this paper, the coalescence pressure of tube with dual cracks is evaluated based on detailed three-dimensional elastic-plastic finite element analyses. In terms of the crack configuration, collinear axial through-wall cracks with various length, distance and ratio between individual cracks are selected. The applicability of failure pressure prediction models recently proposed by the authors was verified by comparing the finite element analyses results with corresponding experimental data for tubes with two identical cracks. Further, in order to quantify the effect of crack length ratio on failure behavior, the failure pressure prediction model was used expansively for tubes containing different-sized cracks and a coalescence evaluation diagram was developed.

Original languageEnglish
Pages (from-to)1460-1467
Number of pages8
JournalNuclear Engineering and Design
Volume237
Issue number12-13
DOIs
StatePublished - Jul 2007

Fingerprint

Dive into the research topics of 'Coalescence evaluation of collinear axial through-wall cracks in steam generator tubes'. Together they form a unique fingerprint.

Cite this