TY - JOUR
T1 - Continuous Online Titer Monitoring in CHO Cell Culture Supernatant Using a Herringbone Nanofluidic Filter Array
AU - Rohskopf, Zhumei
AU - Kwon, Taehong
AU - Ko, Sung Hee
AU - Bozinovski, Dragana
AU - Jeon, Hyungkook
AU - Mohan, Naresh
AU - Springs, Stacy L.
AU - Han, Jongyoon
N1 - Publisher Copyright:
© 2023 American Chemical Society.
PY - 2023/10/3
Y1 - 2023/10/3
N2 - Online monitoring of monoclonal antibody product titers throughout biologics process development and production enables rapid bioprocess decision-making and process optimization. Conventional analytical methods, including high-performance liquid chromatography and turbidimetry, typically require interfacing with an automated sampling system capable of online sampling and fractionation, which suffers from increased cost, a higher risk of failure, and a higher mechanical complexity of the system. In this study, a novel nanofluidic system for continuous direct (no sample preparation) IgG titer measurements was investigated. Tumor necrosis factor α (TNF-α), conjugated with fluorophores, was utilized as a selective binder for adalimumab in the unprocessed cell culture supernatant. The nanofluidic device can separate the bound complex from unbound TNF-α and selectively concentrate the bound complex for high-sensitivity detection. Based on the fluorescence intensity from the concentrated bound complex, a fluorescence intensity versus titer curve can be generated, which was used to determine the titer of samples from filtered, unpurified Chinese hamster ovary cell cultures continuously. The system performed direct monitoring of IgG titers with nanomolar resolution and showed a good correlation with the biolayer interferometry assays. Furthermore, by variation of the concentration of the indicator (TNF-α), the dynamic range of the system can be tuned and further expanded.
AB - Online monitoring of monoclonal antibody product titers throughout biologics process development and production enables rapid bioprocess decision-making and process optimization. Conventional analytical methods, including high-performance liquid chromatography and turbidimetry, typically require interfacing with an automated sampling system capable of online sampling and fractionation, which suffers from increased cost, a higher risk of failure, and a higher mechanical complexity of the system. In this study, a novel nanofluidic system for continuous direct (no sample preparation) IgG titer measurements was investigated. Tumor necrosis factor α (TNF-α), conjugated with fluorophores, was utilized as a selective binder for adalimumab in the unprocessed cell culture supernatant. The nanofluidic device can separate the bound complex from unbound TNF-α and selectively concentrate the bound complex for high-sensitivity detection. Based on the fluorescence intensity from the concentrated bound complex, a fluorescence intensity versus titer curve can be generated, which was used to determine the titer of samples from filtered, unpurified Chinese hamster ovary cell cultures continuously. The system performed direct monitoring of IgG titers with nanomolar resolution and showed a good correlation with the biolayer interferometry assays. Furthermore, by variation of the concentration of the indicator (TNF-α), the dynamic range of the system can be tuned and further expanded.
UR - http://www.scopus.com/inward/record.url?scp=85174846227&partnerID=8YFLogxK
U2 - 10.1021/acs.analchem.3c02104
DO - 10.1021/acs.analchem.3c02104
M3 - Article
AN - SCOPUS:85174846227
SN - 0003-2700
VL - 95
SP - 14608
EP - 14615
JO - Analytical Chemistry
JF - Analytical Chemistry
IS - 39
ER -