Abstract
To reduce CO2 emissions of concrete, a slag-based zero-cement concrete (ZC) of high strength (60 MPa [8.70 ksi]) was developed.In the present study, cyclic loading tests were conducted to investigate the seismic performance of full-scale interior precast beam-column joints using the new ZC.One monolithic portland cement-based normal concrete (NC) beam-column joint and two precast ZC beam-column joints were tested.The test parameters included concrete type, fabrication method, and beam bottom bar anchorage detail.The structural performance was evaluated, including the strength, deformation capacity, damage mode, and energy dissipation.The test results showed that the structural performance of the precast ZC beam-column joints could be equivalent, or superior, to that of the monolithic NC beam-column joint.Although the reinforcement details of the ZC joints do not satisfy the seismic design requirements of special moment frames in ACI 318-19, the seismic performance of the ZC joints satisfied the requirements of ACI 374.1-05 and AIJ 2002 Guidelines.
Original language | English |
---|---|
Pages (from-to) | 117-128 |
Number of pages | 12 |
Journal | ACI Structural Journal |
Volume | 122 |
Issue number | 1 |
DOIs | |
State | Published - Jan 2025 |
Keywords
- beam-column joint
- cyclic loading test
- hook anchorage
- precast concrete
- seismic performance
- slag-based concrete
- zero-cement concrete (ZC)