Abstract
This paper proposes a new diagnosis method of an open-switch fault and fault-tolerant control strategy for T-type three-level inverter systems. The location of the faulty switch can be identified by the average of the normalized phase current and the change of the neutral-point voltage. The proposed fault-tolerant strategy is explained by dividing into two cases: the faulty condition of half-bridge switches and neutral-point switches. The performance of the T-type inverter system improves considerably by the proposed fault-tolerant algorithm when a switch fails. The proposed method does not require additional components and complex calculations. Simulation and experimental results verify the feasibility of the proposed fault diagnosis and fault-tolerant control strategy.
| Original language | English |
|---|---|
| Article number | 6542725 |
| Pages (from-to) | 495-508 |
| Number of pages | 14 |
| Journal | IEEE Transactions on Industry Applications |
| Volume | 50 |
| Issue number | 1 |
| DOIs | |
| State | Published - 2014 |
Keywords
- Fault tolerance
- multilevel
- open-switch fault
- reliability
- T-type inverter
Fingerprint
Dive into the research topics of 'Diagnosis and tolerant strategy of an open-switch fault for t-type three-level inverter systems'. Together they form a unique fingerprint.Cite this