TY - JOUR
T1 - Erratum
T2 - Fully-automated and field-deployable blood leukocyte separation platform using multi-dimensional double spiral (MDDS) inertial microfluidics (Lab Chip (2020) 20 (3612–3624) DOI: 10.1039/D0LC00675K)
AU - Jeon, Hyungkook
AU - Jundi, Bakr
AU - Choi, Kyungyong
AU - Ryu, Hyunryul
AU - Levy, Bruce D.
AU - Lim, Geunbae
AU - Han, Jongyoon
N1 - Publisher Copyright:
© 2023 The Royal Society of Chemistry.
PY - 2023/4/6
Y1 - 2023/4/6
N2 - On page 3614, in the section “3.1. Design of the multi-dimensional double spiral (MDDS) device” there is an error in the sentence “Generally (for moderate flow rate conditions with a constraint of the Dean number, De = Rc(Dh/2r)1/2 < 75, where d = Dh/2r and r represent the curvature ratio and the average radius of curvature of the channel, respectively),42 in the case of smallCRs (<0.07), the net lift force applied to particles is negligible compared to the Dean drag force, resulting in the circulating motion of particles without focusing (the non-focusing mode).40,41” This sentence should read “Generally (for moderate flow rateconditions with a constraint of the Dean number, De = Rc(Dh/2r)1/2 < 75, where d = Dh/2r and r represent the curvature ratio and the average radius of curvature of the channel, respectively),42 in the case of small CRs (<0.01), the net lift force applied to particles is negligible compared to the Dean drag force, resulting in the circulating motion of particles without focusing (the nonfocusing mode).40,41”This change does not affect any of the results or conclusions of the article. The Royal Society of Chemistry apologises for these errors and any consequent inconvenience to authors and readers.
AB - On page 3614, in the section “3.1. Design of the multi-dimensional double spiral (MDDS) device” there is an error in the sentence “Generally (for moderate flow rate conditions with a constraint of the Dean number, De = Rc(Dh/2r)1/2 < 75, where d = Dh/2r and r represent the curvature ratio and the average radius of curvature of the channel, respectively),42 in the case of smallCRs (<0.07), the net lift force applied to particles is negligible compared to the Dean drag force, resulting in the circulating motion of particles without focusing (the non-focusing mode).40,41” This sentence should read “Generally (for moderate flow rateconditions with a constraint of the Dean number, De = Rc(Dh/2r)1/2 < 75, where d = Dh/2r and r represent the curvature ratio and the average radius of curvature of the channel, respectively),42 in the case of small CRs (<0.01), the net lift force applied to particles is negligible compared to the Dean drag force, resulting in the circulating motion of particles without focusing (the nonfocusing mode).40,41”This change does not affect any of the results or conclusions of the article. The Royal Society of Chemistry apologises for these errors and any consequent inconvenience to authors and readers.
UR - http://www.scopus.com/inward/record.url?scp=85152725038&partnerID=8YFLogxK
U2 - 10.1039/d3lc90038j
DO - 10.1039/d3lc90038j
M3 - Comment/debate
C2 - 37021431
AN - SCOPUS:85152725038
SN - 1473-0197
VL - 23
SP - 2356
JO - Lab on a Chip
JF - Lab on a Chip
IS - 9
ER -