Abstract
It was attempted to assess nondestructively the degree of isothermal degradation of 2.25Cr-1Mo steel by using high frequency longitudinal ultrasonic wave. Microstructural parameter (mean size of carbides), mechanical property (Vickers hardness) and ultrasonic attenuation coefficient were measured for the 2.25Cr-1Mo steel isothermally degraded at 630°C for up to 4800 hours in order to find the correlation among these parameters. The ultrasonic attenuation coefficients at high frequencies (over 35 MHz) were observed to increase rapidly in the initial 1000 hours of degradation time and then slowly thereafter, while the ones at low frequencies showed no noticeable increase. Ultrasonic attenuation at high frequencies increased as a function of mean size of carbides. Ultrasonic attenuation coefficient was found to have a linear correlation with the hardness, and suggested accordingly as a potential nondestructive evaluation parameter for assessing the mechanical strength reduction of the isothermally degraded 2.25Cr-1Mo steel.
Original language | English |
---|---|
Pages (from-to) | 257-260 |
Number of pages | 4 |
Journal | Materials Science Forum |
Volume | 475-479 |
Issue number | I |
DOIs | |
State | Published - 2005 |
Event | PRICM 5: The Fifth Pacific Rim International Conference on Advanced Materials and Processing - Beijing, China Duration: 2 Nov 2004 → 5 Nov 2004 |
Keywords
- 2.25Cr-1Mo steel
- Nondestructive evaluation
- Thermal degradation
- Ultrasonic attenuation