TY - JOUR
T1 - Flexible, disposable, and portable self-powered glucose biosensors visible to the naked eye
AU - Lee, Joonyoung
AU - Ji, Jungyeon
AU - Hyun, Kyuhwan
AU - Lee, Heedae
AU - Kwon, Yongchai
N1 - Publisher Copyright:
© 2022 Elsevier B.V.
PY - 2022/12/1
Y1 - 2022/12/1
N2 - Diabetic patients need to measure their blood glucose level ∼5 times a day using glucose sensor. However, typical glucose sensors require additional power supply and equipment to interpret glucose concentration. In this study, flexible, disposable, and portable self-powered glucose biosensor is suggested to quickly measure glucose concentration with the naked eye. The theory of enzymatic biofuel cell is adopted for its self-powered operation. This glucose biosensor includes glucose dehydrogenase (GDH) and Prussian blue (PB) as biocatalysts for anode and cathode, while glucose oxidation reaction and reduction reaction of PB are utilized as the main reactions. In electrochemical evaluations, maximum current density and onset potential of anodic and cathodic reactions are 0.39 and – 0.53 mA/cm2, and 0 and 0.3 V vs. Ag/AgCl. Furthermore, when many interfering compounds are included, anodic catalyst is only sensitive to glucose, while this shows linearity even at a low glucose range of 0.5 – 10 mM (R2 = 0.999). When 3, 5, and 10 mM glucose solutions corresponding to low, normal, and high glucose level are prepared and injected into glucose biosensor, each glucose is well recognized by the naked eye through the number of PB bars whose color is automatically changed after one min.
AB - Diabetic patients need to measure their blood glucose level ∼5 times a day using glucose sensor. However, typical glucose sensors require additional power supply and equipment to interpret glucose concentration. In this study, flexible, disposable, and portable self-powered glucose biosensor is suggested to quickly measure glucose concentration with the naked eye. The theory of enzymatic biofuel cell is adopted for its self-powered operation. This glucose biosensor includes glucose dehydrogenase (GDH) and Prussian blue (PB) as biocatalysts for anode and cathode, while glucose oxidation reaction and reduction reaction of PB are utilized as the main reactions. In electrochemical evaluations, maximum current density and onset potential of anodic and cathodic reactions are 0.39 and – 0.53 mA/cm2, and 0 and 0.3 V vs. Ag/AgCl. Furthermore, when many interfering compounds are included, anodic catalyst is only sensitive to glucose, while this shows linearity even at a low glucose range of 0.5 – 10 mM (R2 = 0.999). When 3, 5, and 10 mM glucose solutions corresponding to low, normal, and high glucose level are prepared and injected into glucose biosensor, each glucose is well recognized by the naked eye through the number of PB bars whose color is automatically changed after one min.
KW - Enzymatic biofuel cell
KW - Glucose dehydrogenase
KW - Prussian blue
KW - Prussian white
KW - Self-powered glucose biosensor
UR - http://www.scopus.com/inward/record.url?scp=85138056235&partnerID=8YFLogxK
U2 - 10.1016/j.snb.2022.132647
DO - 10.1016/j.snb.2022.132647
M3 - Article
AN - SCOPUS:85138056235
SN - 0925-4005
VL - 372
JO - Sensors and Actuators, B: Chemical
JF - Sensors and Actuators, B: Chemical
M1 - 132647
ER -