Abstract
With the recent trend to construct high-rise and large buildings, the steel structure system is widely used, but there are not enough studies on the vibration characteristics of the iFLASH system on the buildings. Therefore, in this study, we performed a vibration measurement of the natural frequency and damping ratio in the stage of iFLASH panel, composit, frame completion and cladding completion. The result findings suggest that the damping ratio after the cladding completion has a greater effect on the reduction of the damping ratio, than the stage after the frame completion.
| Translated title of the contribution | Vibration Characteristics of iFLASH System |
|---|---|
| Original language | Korean |
| Pages (from-to) | 89-97 |
| Number of pages | 9 |
| Journal | 한국공간구조학회지 |
| Volume | 16 |
| Issue number | 3 |
| DOIs | |
| State | Published - Sep 2016 |