@inproceedings{2aa54704b9d147608c6febd1b4bcb27a,
title = "Load-adaptive soft-switching energy recovery sustainer for plasma display",
abstract = "In this paper, an energy recovery for plasma display is proposed. The proposed energy recovery sustainer provides soft-switching of main sustain switches and reduces the switching loss. Due to soft-switching characteristic, the switching losses of main switches are significantly reduced. In addition, the conduction losses in both main and auxiliary switches are effectively reduced by varying a current build-up time according to image patterns. Theoretical analysis and performance of the proposed energy recovery sustain driver were verified on an experimental prototype operating at 200 kHz switching frequency.",
keywords = "Energy recovery, Load-adaptive, Plasma display, Soft-switching, Sustainer",
author = "Do, \{H. L.\}",
year = "2013",
doi = "10.4028/www.scientific.net/AMM.241-244.632",
language = "English",
isbn = "9783037855461",
series = "Applied Mechanics and Materials",
pages = "632--635",
booktitle = "Industrial Instrumentation and Control Systems",
note = "2012 International Conference on Measurement, Instrumentation and Automation, ICMIA 2012 ; Conference date: 15-09-2012 Through 16-09-2012",
}