Abstract

PET image of tumor located in thoracic region was affected by various organ motions such as respiration and heartbeat. Thoracic motion is difficult to estimate and correct accurately using external measurement or anatomical image solely. The aim of this study was to compare the accuracy of motion correction using PET fiducial mark and 3D MRI image. The radioactive bead for PET fiducial mark was realized from molecular sieve contained 0.37 MBq F-18 and placed in thoracic region. PET study was performed using a small animal PET scanner after IV injection of FDG. MRI study was performed using 3-T clinical MRI system with 3D T1-VIBE (TR/TE=5.67/1.42 ms) sequence. Motion corrected PET image was created by mutual information registration with B-Spline interpolation to the mean image after first realignment. FWHM of lung and liver region in static PET image was 4.77±0.87 and 4.81±0.45, respectively. Measured FWHM of lung region in motion corrected PET image using PET fiducial mark and 3D VIBE MRI was measured 4.22±0.09 and 4.59±0.06, respectively. In case of liver region, FWHM was measured 4.47±0.16 and 4.65±0.25 respectively. The improvement of resolution was observed by proper correction method. In this study PET correction was implemented by motion information extracted from various images. These results suggest motion correction would be possible without external device or fiducial mark using MRI motion data. Motion correction using MRI should be considered acquisition method and organ region in accordance with motion characteristics.

Original languageEnglish
Title of host publicationMedical Imaging 2013
Subtitle of host publicationPhysics of Medical Imaging
DOIs
StatePublished - 2013
EventMedical Imaging 2013: Physics of Medical Imaging - Lake Buena Vista, FL, United States
Duration: 11 Feb 201314 Feb 2013

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume8668
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2013: Physics of Medical Imaging
Country/TerritoryUnited States
CityLake Buena Vista, FL
Period11/02/1314/02/13

Keywords

  • Molecular sieve
  • Motion correction
  • Motion estimation
  • MRI
  • PET
  • Radioactive bead
  • Thoracic motion

Fingerprint

Dive into the research topics of 'Motion correction of rodent thoracic PET image using radioactive bead and MRI image'. Together they form a unique fingerprint.

Cite this