Abstract
This paper presents a neutral-point voltage balancing method for three-level inverter systems using a time-offset estimation scheme. The neutral-point voltage is balanced by adding a time-offset to the turn-on time of the switches. If an inaccurate time-offset is added, the neutral-point deviation still remains. An accurate time-offset is obtained through the proposed time-offset estimation scheme. This method is implemented without additional hardware, complex calculations, or analysis. The effectiveness of the proposed method is verified by experiments.
| Original language | English |
|---|---|
| Pages (from-to) | 243-249 |
| Number of pages | 7 |
| Journal | Journal of Power Electronics |
| Volume | 13 |
| Issue number | 2 |
| DOIs | |
| State | Published - Mar 2013 |
Keywords
- Multilevel
- Neutral-point voltage balancing
- NPC inverter