Abstract
Since multi-view images can be utilized for 3D visualization and surveying as well, a system calibration is an essential procedure. The cameras in the system are mounted to the holder and their locations and attitudes are relatively fixed. Therefore, the locations and the attitudes of the perspective centers of the four oblique looking cameras can be calculated using the location and attitude of the nadir looking camera and the boresight values between the cameras. In this regard, this research is focusing on the analysis of the relative location and attitude between the nadir and oblique looking cameras based on the results of the exterior orientation parameters after the aerial triangulation of the real multiview images. We acquired high standard deviations of the relative locations between the nadir and oblique cameras. Standard deviations of the relative attitudes between the cameras were low when only the exterior orientations of the oblique looking cameras were allowed to be adjusted. Moreover, low standard deviations of the relative attitudes came when we considered not all the exterior orientations of the cameras but the attitudes of them only.
| Original language | English |
|---|---|
| Pages (from-to) | 369-375 |
| Number of pages | 7 |
| Journal | Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography |
| Volume | 28 |
| Issue number | 3 |
| State | Published - 2010 |
Keywords
- Camera system calibration
- Multi-view Camera System
- Oblique Image
- Platform modeling