Quality monitoring of thermally degraded stationary gas turbine blade material by surface wave technique

J. W. Byeon, C. S. Kim, J. H. Song, S. I. Kwun

Research output: Contribution to journalArticlepeer-review

Abstract

For the quality monitoring and reliable application of stationary gas turbine blade (vane), near surface damages in the isothermally degraded vein material (i.e., cobalt based superalloy) were characterized by ultrasonic surface wave technique. Surface wave velocity and attenuation were measured for the artificially degraded specimens at 1100°C, together with microstructural analysis and micro-hardness measurement. Surface wave velocity increased with thermal degradation time, which was attributed to the increasing depletion of solute chromium near the surface. Strong frequency dependence of surface wave velocity was observed in the specimens with surface depletion layer. Attenuation coefficient of surface wave increased with increasing degradation time. The potential of ultrasonic surface wave technique to assess near surface damages in vein material was discussed with an emphasis on the relationship between the microstructural damage and the governing principles of ultrasonic response.

Original languageEnglish
Pages (from-to)1998-2003
Number of pages6
JournalKey Engineering Materials
Volume297-300 III
DOIs
StatePublished - 2005

Keywords

  • Nondestructive evaluation
  • Stationary gas turbine blade
  • Thermal degradation microstructure
  • Ultrasonic surface wave

Fingerprint

Dive into the research topics of 'Quality monitoring of thermally degraded stationary gas turbine blade material by surface wave technique'. Together they form a unique fingerprint.