Robust Tracking Control of a Three-phase Charger under Unbalanced Grid Condition

Chivon Choeung, Meng Leang Kry, Young Il Lee

Research output: Contribution to journalArticlepeer-review

15 Scopus citations

Abstract

This paper presents a robust control technique for three-phase charger under unbalanced grid conditions. The control method consists of inner-loop robust grid-current control and outer-loop proportional integral control for constant current (CC) and constant voltage (CV) control. A dual-current control for the inner-loop positive and negative sequence is employed to eliminate the unbalanced current caused by the grid so that a constant current and voltage can be provided to the batteries. The inner-loop robust controllers utilize state feedback with integral action in the dq-synchronous frame. A linear matrix inequality-based optimization scheme is used to determine stabilizing gains of the controllers to maximize the convergence rate to steady state in the presence of uncertainties. The uncertainties of the system are described as the potential variation range of the inductance and resistance in the L-filter.

Original languageEnglish
Pages (from-to)173-178
Number of pages6
JournalIFAC-PapersOnLine
Volume51
Issue number28
DOIs
StatePublished - 2018

Keywords

  • Battery charger
  • fast charging
  • linear matrix inequality (LMI)
  • robust control
  • unbalanced grid

Fingerprint

Dive into the research topics of 'Robust Tracking Control of a Three-phase Charger under Unbalanced Grid Condition'. Together they form a unique fingerprint.