Skip to main navigation Skip to search Skip to main content

Selection of the optimal channel configuration for implementing wearable EEG devices for the diagnosis of mild cognitive impairment

  • Kyeonggu Lee
  • , Kang Min Choi
  • , Seonghun Park
  • , Seung Hwan Lee
  • , Chang Hwan Im
  • Hanyang University
  • Inje University

Research output: Contribution to journalArticlepeer-review

36 Scopus citations

Abstract

Background: Early diagnosis of mild cognitive impairment (MCI) is essential for timely treatment planning. With recent advances in the wearable technology, interest has increasingly shifted toward computer-aided self-diagnosis of MCI using wearable electroencephalography (EEG) devices in daily life. However, no study so far has investigated the optimal electrode configurations for the efficient diagnosis of MCI while considering the design factors of wearable EEG devices. In this study, we aimed to determine the optimal channel configurations of wearable EEG devices for the computer-aided diagnosis of MCI. Method: We employed an EEG dataset collected from 21 patients with MCI and 21 healthy control subjects. After evaluating the classification accuracies for all possible electrode configurations for the two-, four-, six-, and eight-electrode conditions using a support vector machine, the optimal electrode configurations that provide the highest diagnostic accuracy were suggested for each electrode condition. Results: The highest classification accuracies of 74.04% ± 4.82, 82.43% ± 6.14, 86.28% ± 2.81, and 86.85% ± 4.97 were achieved for the optimal two-, four-, six-, and eight-electrode configurations, respectively, which demonstrated the possibility of precise machine-learning-based diagnosis of MCI with a limited number of EEG electrodes. Additionally, further simulations with the EEG dataset revealed that the optimal electrode configurations had significantly higher classification accuracies than commercial EEG devices with the same number of electrodes, which suggested the importance of electrode configuration optimization for wearable EEG devices based on clinical EEG datasets. Conclusions: This study highlighted that the optimization of the electrode configuration, assuming the wearable EEG devices can potentially be utilized for daily life monitoring of MCI, is necessary to enhance the performance and portability.

Original languageEnglish
Article number170
JournalAlzheimer's Research and Therapy
Volume14
Issue number1
DOIs
StatePublished - Dec 2022

Keywords

  • Electroencephalography
  • Machine learning
  • Mild cognitive impairment
  • Optimal channel configuration
  • Wearable EEG device

Fingerprint

Dive into the research topics of 'Selection of the optimal channel configuration for implementing wearable EEG devices for the diagnosis of mild cognitive impairment'. Together they form a unique fingerprint.

Cite this