Abstract
In the preliminary design phase of explosion-proof structures, the use of P-I diagram is useful. Based on the fact that the deformation criteria at failure or heavy damage is significantly larger than the yield deformation, a closed form solution of normalized P-I diagram is proposed using the complete plastic resistance curve. When actual sizes and material properties of RC structural component are considered, the complete plasticity assumption shows only a maximum error of 6% in terms of strain energy, and a maximum difference of 9% of the amount of explosives in CWSD.
| Original language | English |
|---|---|
| Pages (from-to) | 509-514 |
| Number of pages | 6 |
| Journal | Advances in Concrete Construction |
| Volume | 10 |
| Issue number | 6 |
| DOIs | |
| State | Published - Dec 2020 |
Keywords
- closed form solution
- explosion
- P-I diagram
- support rotation angle