Abstract
A new measurement method is suggested to quantify the phosphate poisoning of cathodic Pt catalyst for HT-PEMFC. To do that, hydrogen peroxide was used as an indicator to reduce the error which has been occurred in conventional electrochemical measurement such as CV or ORR RDE with high concentration of phosphate ions. As a result, the current density induced from the reaction of hydrogen peroxide decomposition increased proportionally to the concentration of phosphate ion while the conventional methods show has a significant error with high concentration of phosphate ion. Thus, it is confirmed that the suggested way is superior to the conventional measurement method for the quantification of phosphate ion poisoning in an atmosphere similar to the actual operation condition of HT-PEMFC.
| Original language | English |
|---|---|
| Pages (from-to) | 438-443 |
| Number of pages | 6 |
| Journal | Korean Chemical Engineering Research |
| Volume | 57 |
| Issue number | 3 |
| DOIs | |
| State | Published - 2019 |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 7 Affordable and Clean Energy
Keywords
- Hydrogen peroxide
- PEMFC
- Phosphoric acid
- Platinum catalyst
- Poisoning mechanism
Fingerprint
Dive into the research topics of 'The measurement method using hydrogen peroxide for quantification of phosphate ion poisoning of pt based catalyst'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver